SP - Module 5 - Commissioning

Content
28 modules

Difficulty
Intermediate

Rating

Course Length
6 hours

Instructor
Ryan Coleman

Description

The commissioning module is focused on testing installed systems to ensure quality installs and optimal performance. Checklists are provided in this module for contractors to use in the field and ensure consistent work. As appropriate, this section will reference existing commissioning checklists (e.g. FortisBC gas furnace rebate commissioning checklist).

Objectives

  • Different types of testing of installed systems to ensure quality installs and optimal performance
  • Checklists for contractors to use in the field and ensure consistent work

1.
Welcome
{{ vm.helper.t('reports.module') }}
2.
Module 5 &6 Kickoff Webinar Replay (1:07:57)
{{ vm.helper.t('reports.module') }}
3.
Commissioning (04:11)
{{ vm.helper.t('reports.module') }}
4.
System Testing (14:43)
{{ vm.helper.t('reports.module') }}
5.
Equipment Start Up and Handover Video
{{ vm.helper.t('reports.module') }}
6.
Understanding Performance Calculations and Results (External Video 12:45)
{{ vm.helper.t('reports.module') }}
7.
It's Time for a Knowledge Check!
{{ vm.helper.t('reports.module') }}
8.
Knowledge Check
{{ vm.helper.t('courses.exam') }}
9.
Share Your Knowledge in the Forum!
{{ vm.helper.t('reports.module') }}
10.
Firing Rate for Fossil Fuel-Fired Equipment (26:58)
{{ vm.helper.t('reports.module') }}
11.
Clocking the Gas Meter Interactive Exercise
{{ vm.helper.t('reports.module') }}
12.
It's Time for a Knowledge Check!
{{ vm.helper.t('reports.module') }}
13.
Knowledge Check
{{ vm.helper.t('courses.exam') }}
14.
Airflow Across Indoor Heat Exchanges (32:24)
{{ vm.helper.t('reports.module') }}
15.
Interactive Exercise: Predicting Capacity of Old Duct Systems for New Airflow Requirements
{{ vm.helper.t('reports.module') }}
16.
It's Time for a Knowledge Check!
{{ vm.helper.t('reports.module') }}
17.
Knowledge Check
{{ vm.helper.t('courses.exam') }}
18.
Tools (20:14)
{{ vm.helper.t('reports.module') }}
19.
Measurements (38:27)
{{ vm.helper.t('reports.module') }}
20.
How to Use MeasureQuick (External Video Resource 21:48)
{{ vm.helper.t('reports.module') }}
21.
Refrigerant Charge (40:12)
{{ vm.helper.t('reports.module') }}
22.
It's Time for a Knowledge Check!
{{ vm.helper.t('reports.module') }}
23.
Knowledge Check
{{ vm.helper.t('courses.exam') }}
24.
Checklists and Test Reports (05:15)
{{ vm.helper.t('reports.module') }}
25.
It's Time for a Knowledge Check!
{{ vm.helper.t('reports.module') }}
26.
Knowledge Check
{{ vm.helper.t('courses.exam') }}
27.
Helpful Links and Resources
{{ vm.helper.t('reports.module') }}
28.
Wrap Up
{{ vm.helper.t('reports.module') }}
 
Added 18 days ago, by Anonymous
When making calculations, it was be nice if it was specified that you need to use only one decimal point, otherwise you can get the answer wrong, even if the calculation you made is more accurate than the quiz "correct" answer.
 
Added about 1 month ago, by Jaylene
good
 
Added about 1 month ago, by William
Useful information
 
Added 3 months ago, by Traven
lots of knowladge learned alot
 
Added 3 months ago, by Anonymous
Thanks
 
Added 4 months ago, by Anonymous
good
 
Added 4 months ago, by Anonymous
Informative.
 
Added 4 months ago, by Jason
I was taught the airflow calculation was (output/TR) divided by 1.08 I had a different CFM originally and got the question wrong but followed this math and got it correct the second time. Very informative, thank you.
 
Added 5 months ago, by Lian
.
 
Added 5 months ago, by Kimberly
Thank you for all the great information.

Shopping Cart

Your cart is empty